EMI/EMC Test and Measurement |
|
Features :E-field Shielding better than 100 dB from 30 MHz. Applications :Radiated emission and susceptibility of electrical or electronics product can be measured upto 1 GHz. Users :Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. |
Service name :Measurement of Radiated emission from electrical or electronic product as per CISPR 11,22 FCC part 15 standard. Features :Measurement distance can be set 3M and Rx antenna height can be varied from 1M to 4M. 360º azimuth rotation of the EUT can be given. Applications :Electrical or electronics product with input current less than 20A. Users :Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. Other Detail :Facility is FCC listed. Radiated emission can be measured from 30MHz to 1 GHz. |
Service name :Radiated susceptibility test of electrical or electronic product as per IEC 61000-4-3 standard. Features :Measurement distance can be set 3M and Field upto 10 V/M can be created on the EUT. Field uniformity better than 6dB for 75% or more test points. Applications :Measurement distance can be set 3M and Field upto 10 V/M can be created on the EUT. Field uniformity better than 6dB for 75% or more test points. Users :Railway vendors and other Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. Other Detail :Radiated susceptibility can be tested from 80MHz to 1 GHz and sine wave modulation at 1KHz with 80% modulation depth. |
Service name :Magnetic field Immunity test of electrical or electronic product as per IEC 61000-4-8 standard. Features :Field Immunity can be tested at 50Hz. Severity level can be upto 300 A/m for continuous and upto 1000 A/m for short duration. Applications :Electronics product with CRT display with input current less than 20A. Users :Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. Other Detail :Immunity can be tested at power line frequency and field strength upto 5 Gauss. |
Service name :Measurement of conducted emission from electrical or electronic product as per CISPR 11,22 FCC part 15 standard. Features :Conducted emission measurement of 3 phase EUT is possible and input current upto 25A. Applications :Electrical or electronics product. Users :Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. Other Detail :Conducted Emission can be measured from 150KHz to 30MHz and also as per FCC standard. |
Service name :ESD test of electrical or electronic product as per IEC 61000-4-2 standard. Features :The severity level for air discharge is upto ±15 KV and contact discharge is upto ±8 KV. Pulse rise time is between 0.7nS to 1nS. Applications :Electronic equipment sensitive to static discharge. Users :Railway vendors and other Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. Other Detail :ESD test of EUT can be carried out upto ±15 KV. |
Service name :EFT/Burst test of electrical or electronic product as per IEC 61000-4-4 standard. Features :Pulse Rise time is 5 nS, Pulse width is 50 nS, Burst duration is 15 mS, Burst Period is 300 mS and Test voltage upto ± 4 KV Applications :Electrical or electronic equipment with input current less than 16A. Users :Railway vendors and other Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. Other Detail :EFT/Burst of EUT can be carried out upto ±4 KV and upto 5 KHz repetition rate. |
Service name :High energy surge immunity test of electrical or electronic product as per IEC 61000-4-5 standard. Features :Pulse Rise time is 1.2 mS, Pulse width is 50 mS and Test voltage upto ± 4 KV. Applications :Electrical or electronic equipment with input current less than 16A. Users :Railway vendors and other Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. Other Detail :Surge generator can deliver 1.2/50mS voltage surge across high load resistance and 8/20mS current surge into a short circuit. |
Service name :Measurement of Harmonic current emission from electrical or electronic product as per IEC 61000-3-2 standard. Features :5KVA programmable source and automated measurement. Applications :Electrical or electronic equipment with input current less than 16A. Users :Industries in and around Kolkata and Eastern India. Location of facility :SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex. Other Detail :Harmonic current emission from EUT can be carried out upto 16A input current. |
|
|
|
|
|
|
|
|
: F e a t u r e s : Microwave & millimeterwave measurements :
» Vector Network Analyzer
» Scalar Network Analyzer.
» Spectrum Analyzer.
» Power Meter.
» Phase Noise & Noise figure
» Signal Generator
» Antenna Measurement
Instrumentation.
Microwave Integrated Circuit Fabrication :
» Clean room.
» Laser pattern Generator.
» PCB Fabrication machine.
» Goldwire Bonder.
» Flip Chip Bonder.
» Die Bonder.
» Inspection Microscope.
» Profilometer.
» Weller Soldering station.
EMI/EMC Measurements :
» 3M Ferrite Tiled Shielded
Anechoic Chamber.
» Radiated Emission test facility.
» Radiated Susceptibility test
facility.
» Magnetic Field Immunity test
facility.
» Conducted Emission test
facility.
» Electro Static Discharge test
facility.
» Electrical Fast Transient / Burst
test Facility.
» High Energy Surge test facility.
» Harmonics Emission test facility.
» EMI/EMC Consultancy.
[NABL Accreditation under process]
CAD Tools :
» Circuit Simulators.
» HFSS 10.1
» CST microwave studio 2006.
» ADS 2007
» Ansoft Designer 3.5
» IE3D
Mechanical CAD :
» Auto CAD.
» Inventer.
» ProE.
MIC Facility :
Precision Mechanical Fabrication Facilities :
» Lathe.
» Conventional Vertical Milling.
» CNC wire cut EDM.
» CNC Vertical Machining Centre.
» Hydraulic Surface Grinding.
» Precesion Portable Lathe.
» Double Lapping machine. |
|
|
|
|
|
No comments: